1271836 - HEATER, 8.5MM BTU.HR, 150#, 640°F, HOT OIL, GAS FIRED, ECLIPSE, REFURBISHED [1]

  • MFD.BY:Eclipse. Chattanooga TN
  • DATE MFD:1971
  • TYPE:Hot Oil. Thermal Fluid Heater, liquid phase
  • MODEL:800HC LT WP.CGO.AAL.PRO.FM
  • SIZE:8'dia. X 23'6"long
  • STYLE:Horizontal
  • MAT'L.CONSTRN:CS
  • TUBES:CS spiral, approx. 4"dia., 52 turns @ 78"dia, 4" Conns.
  • EFFECTIVE AREA:1310 SF approx.
  • BTU/HR:12.5MM BTU/Hr input. 8.5MM BTU/Hr absorbed nominal. Max- 14.5MM BTU/Hr input. 10.15MM BTU/Hr absorbed @ 70% efficiency [Originally 12.143MM BTU/HR input approx. 8.5 mm btu/hr absorbed]
  • COMBUSTION-BURNER(S):Yes. 12.5MM Btu/Hr. Original burner N/A, was 12.143MM BTU/HR input. Includes new replacement Webster JB Series 3G100 linkage type burner and gas train w/controls up to 12.5MM Btu/Hr input. UL-CSD-1 compliant, non-weatherproof package, wired, piped, test f
  • COMBUSTION-BLOWER:10HP
  • TEMPERATURE:640°F approx.
  • PRESSURE:150#MAWP approx.
  • CIRCULATION PUMP:Dean mdl. R434, 3 X 4 X 10, 360GPM @ 195TDH less/30HP motor, 3/60/460v, 1750rpm. 2 available, extra.
  • THERMAL FLUID:Dowtherm A. 737 gallons to fill.
  • PRIOR SVC:HC heat transfer
  • COMMENTS:Stack flanged, CS, 30"dia. Original 40'high, not included. Refurbishing includes external sandblast and paint, new burner pkg with blower, gas train and local controls, new temperature control panel, wired, coil pressure test and test firing. Delivery 30d
  • SHIPPING SIZE-W X H X L:9'1"W X 11'1"H X 28'L
  • APPROX. WEIGHT-LBS:30900#
  • QUANTITY:1

Technical