PROCESS:Glycol, Water & Ethanol Distillation & Recovery system. 3 lines in parallel operation. Distillation process- Product pumped through horizontal Distillation kettles with steam Re-Boilers and Distillation Columns with shell and tube Condensers.
PRIMARY PRODUCT(S):Glycol, Ethanol.
PRIMARY PROD.CAPACITY:300gpm total feed. 100gpm per line.
PRIMARY PROD.DETAIL:4 Fractions per Line- #1 Methanol. Line #2 Off-Specs, Line #3 Distilled Glycol, Line #4 Off-Specs
SECONDARY PRODUCT(S):Water
MAT'LS CNSTRN-CONTACTS:316SS product & CS
INSTALLATION AREA:70' x 100'
PRIOR SERVICE:Nylon Polymer production. Last use 2003 approx.
COMMENTS:Installed, units side by side in 3 story open frame structure. Flow controllers, Temperature controllers, High/Low level alarms. Control room for all 3 units. Documentation. Heating Exchangers rated 400# @ 480 Deg F shellside, FV tubeside in general. Cool