ORIENTATION:Vertical. On 4 legs, 10" I-beam CS, welded to tank sides approx. 2' up side, w/3/16" thick stiffeners between legs and shell/bottom head. Lower tangent line 8'0" elev. with approx. 54" ground clearance from bottom outlet flange. 10" X 12" leg bottom anch
JACKET-TYPE/ZONES/BTM HD/MAT'L:304LSS Dimple. External, 4-zones on shell side, each approx. 36" high, weld attached 12 guage, 304S.S. w/full flow headers, DP75#+ @250°F, w/ 2 @ 2" 150# RFF conns.per zone. Total 372SF area total approx. Alternative 1/2 pipe type jacket available, 3"dia
PRESSURE-JACKET:75# @ 250°F DP
COILS-PRESSURE/TEMP/DXL:Optional. 150# @ 400°F. A./ Internal 2 turns @ 2"dia. sch.80 304SS pipe on 8'6"pitch circle diameter. Approx. 27SF surface area, 53 linear feet, 14SF area, extra. Optional B./ Internal 6 turns @ 2"dia. sch.80. 304SS pipe on 8'6" pitch circle diameter. App
SHELL-LENGTH:12' straight side.
THICKNESSES-TOP/SH/BTM:3/16" Top head, Shell, Bottom head/cone
AGITATOR-HP/RPM:10-50HP typical. Not included. Available extra, new or used. Top entering. Flange mount. (12) radial agitator mounting nozzle gussets, ½" thick, 9" high nozzle projection, 36" NTS on 10"@ 150# RFF.
CONFIGURATION-TOP/BTM:30° cone bottom head, slight cone or F&D top head to suit & per availability for delivery schedule.
SUPPORTS-QTY/TYPE/HIGH:On 4 legs, 10" I-beam CS, welded to tank sides approx. 2' up side, w/3/16" thick stiffeners between legs and shell/bottom head. Lower tangent line 8'0" elev. with approx. 54" ground clearance from bottom outlet flange. 10" X 12" leg bottom anchor pads.
CONNECTIONS-TOP/SH/BTM:Top: 20" dia. manway w/cover, 10"(Agitator/centre), 10", 3"(2), 2"(5), 1½".Shell: 1½", 1"(6) Bottom: 3" cbo. All slip ring flanged. 2" NPT (2) in/out for internal coil.
BAFFLES-QTY/W X L:(4) equispaced internal baffles. 11" X 11' long, 316SS, 3/8" thick, bolted to clips welded to shell side. 1½" wall clearance.
PRIOR SERVICE:UNUSED New fabrication built to suit.
COMMENTS-ASME ETC:Design/Fab Meet/exceed ASME Sec VIII Div I. with calculations based on allowable stress values per Sec II Part D. Welding per ASME Sec IX qualified procedures. Seams to be double butt welds (SMAW). Materials to ASME Sec II. MTR's available. Max. product