TYPE:Finned tube type heat exchanger. Exhaust heat recovery. Economizer. Gas to Liquid.
MODEL:HRSR-260B24.5SSP
AREA-BARE TUBE:782
AREA-EXTENDED:TBD
MAT'L CONSTRN-TUBES:316SS
TUBES:Size/configuration to be determined. Connected to Headers with tube compression fittings.
FINS:304SS. Nickel brazed to tubes.
HEADERS:Terminates in 2 Headers at one end. 316SS.
PRESSURE-MAX:150# MOP Liquid side. Hyd. 225# @ 550Deg F. Gas MDT 750Deg F inlet. ASME stamped.
SECTIONS PER BAY:1
NO. BAYS:1
FANS:NA
DRIVEN BY:NA
DRIVEN VIA:NA
PRIOR SVC:Exhaust heat recovery, water loop heater. 2.126MM BTU/HR recovery. Liquid flow rate 360GPM, inlet 148Deg F, discharge 160.1Deg F, pressure drop 3.19psig. Exhaust gas 9088SCFM in @ 569Deg F, discharge 375Deg F, pressure drop 1.25''WC Max.
COMMENTS:Gas side External shell is 10Ga 304SS, 3" factory blanket wrap type insulation. Hinged full face door for tube/fins inspection. Internal Gas contacts SS. Liquid Headers not insulated, vertical orientation. Single fin tube Row design. NEMA 4 electrical Con