1269243 - HEATER, 18.3MM BTU.HR, 150#, 810°F, HOT OIL, GAS-OIL FIRED, OPTIMIZED [1]

  • MFD.BY:Optimized Process Furnace
  • DATE MFD:1984
  • TYPE:Hot Oil. Thermal Fluid Heater, liquid phase
  • MODEL:Horizontal Box type heater.
  • SIZE:10' wide. X 27'long body approx.
  • STYLE:Horizontal box type w/convection section.
  • MAT'L.CONSTRN:C.S.
  • TUBES:A335 P5 CS, 44 @ 6.625"/4-1/2"OD, 0.237" thick x 26'long. 2-Pass[ Rad]. 8 @ 4-1/2"OD, 0.237" thick x 26'long 2-Pass [Conv].
  • EFFECTIVE AREA:1650 Sq.Ft. approx. [1405 rad/ 245 conv]
  • BTU/HR:18.3MM BTU/HR. Heat absorbed 18.3MM Btu/hr. Heat released 19.9MM Btu/hr. Efficiency 91.75%.[LHV] w/air preheat.
  • COMBUSTION-BURNER(S):[4] 4.975MM Btu heat release ea. Mfd John Zinc VYD-PC Size 14.
  • COMBUSTION-BLOWER:10HP approx.
  • TEMPERATURE:810°F DT
  • PRESSURE:150# DP
  • CIRCULATION PUMP:215,924 PPH oil. 22# pressure drop in heater.
  • THERMAL FLUID:Therminol 55
  • PRIOR SVC:Charge Heater, Vacuum unit reduced crude, 51,750PPH. 60# pressure drop total allowed
  • COMMENTS:Horizontal box type heater. 5" castable refractory lined. 4'3"dia x 50'high 321SS Stack, 60'oah..
  • SHIPPING SIZE-W X H X L:9'6"W X 14'H X 45'L
  • APPROX. WEIGHT-LBS:40000#
  • QUANTITY:1