1270696 - HEATER, 40.2MM BTU.HR, 1000#, 900°F, PETROCHEM, GAS FIRED, F.WHEELER [1]

  • MFD.BY:Foster Wheeler
  • DATE MFD:1961. Refurbished 2001
  • TYPE:Heater, liquid phase
  • SIZE:12'5"dia. X 23'6" tall
  • STYLE:Vertical
  • MAT'L.CONSTRN:C.S.
  • TUBES:40 @ 5"dia. X Sch.40 AW seamless x 21'avg. long, 10' 7-7/8" pitch circle. 304SS [ASTM A312-TP-304H]. 5" 900# RTJ flange. Hydrotested 1500psig. Radiant section- 4'w x 9' long x 6ft high, 36 @ 4-1/2" dia x 0.237" wall, horizontal, 1-pass.
  • EFFECTIVE AREA:1300 total Sq.Ft. approx., 1020 SF Convection, 327 SF approx. Radiant section.
  • BTU/HR:26.8 MM BTU/HR max. input approx. 20.1 MM Btu/Hr absorbed approx. @ 75% Eff. Burners, 4 @ 6.7MM Btu/HR input/max. heat release, 4.1MM Btu/HR normal, 1.53MM Btu/HR. Min.. New installed w/controls 2001.
  • COMBUSTION-BURNER(S):Natural draft. Vertical up direction of firing, on 5'8" circle. Callidus Technologies CUB-6W-CCW Burner Assy [Ultra Blue]. Process Gas Fuel, LHV 849 Btu/SCF design. NOX 0.018Lb/MM Btu/Hr. [HHV]
  • COMBUSTION-BLOWER:NA
  • TEMPERATURE:900°FDT
  • PRESSURE:1000# DP
  • CIRCULATION PUMP:NA
  • THERMAL FLUID:Process oil.
  • PRIOR SVC:Unifiner Charge Heater in hydrocarbons facility, Aromatic Hydrocarbons & Hydrogen. Design 18.84MM Btu/Hr normal, 27.6 originally using 6 @ Peabody S-8" burners and 348 Btu/SCF gas. Process liquid flow 203860Lb/Hr. Inlet 556 Deg F, 830psig, outlet 787 Deg
  • COMMENTS:Installed w/burner and controls, piping, valves and instrumentation. Stack CS, 48"ID x 58'high approx. Main body and convection section 5-1/2" 2000Deg F. firebrick insulation. Sits on 7'9" high concrete piers. Refurbished, retubed and new controls, new b
  • SHIPPING SIZE-W X H X L:9'1"W X 11'1"H X 28'L
  • APPROX. WEIGHT-LBS:100000#
  • QUANTITY:1