COMBUSTION-BURNER(S):Natural draft. Vertical up direction of firing, on 5'8" circle. Callidus Technologies CUB-6W-CCW Burner Assy [Ultra Blue]. Process Gas Fuel, LHV 849 Btu/SCF design. NOX 0.018Lb/MM Btu/Hr. [HHV]
COMBUSTION-BLOWER:NA
TEMPERATURE:900°FDT
PRESSURE:1000# DP
CIRCULATION PUMP:NA
THERMAL FLUID:Process oil.
PRIOR SVC:Unifiner Charge Heater in hydrocarbons facility, Aromatic Hydrocarbons & Hydrogen. Design 18.84MM Btu/Hr normal, 27.6 originally using 6 @ Peabody S-8" burners and 348 Btu/SCF gas. Process liquid flow 203860Lb/Hr. Inlet 556 Deg F, 830psig, outlet 787 Deg
COMMENTS:Installed w/burner and controls, piping, valves and instrumentation. Stack CS, 48"ID x 58'high approx. Main body and convection section 5-1/2" 2000Deg F. firebrick insulation. Sits on 7'9" high concrete piers. Refurbished, retubed and new controls, new b