COMBUSTION-BURNER(S):Yes. 12.5MM Btu/Hr. Original burner N/A, was 12.143MM BTU/HR input. Includes new replacement Webster JB Series 3G100 linkage type burner and gas train w/controls up to 12.5MM Btu/Hr input. UL-CSD-1 compliant, non-weatherproof package, wired, piped, test f
COMBUSTION-BLOWER:10HP
TEMPERATURE:640°F approx.
PRESSURE:150#MAWP approx.
CIRCULATION PUMP:Dean mdl. R434, 3 X 4 X 10, 360GPM @ 195TDH less/30HP motor, 3/60/460v, 1750rpm. 2 available, extra.
THERMAL FLUID:Dowtherm A. 737 gallons to fill.
PRIOR SVC:HC heat transfer
COMMENTS:Stack flanged, CS, 30"dia. Original 40'high, not included. Refurbishing includes external sandblast and paint, new burner pkg with blower, gas train and local controls, new temperature control panel, wired, coil pressure test and test firing. Delivery 30d