1270588 - PLANT, CHEMICAL, GLYCOL-ETHANOL DISTILLATION RECOVERY, 300 GPM, CS & 316SS [1]

  • MFD.BY:Vulcan
  • DATE MFD:1970-74
  • PROCESS:Glycol, Water & Ethanol Distillation & Recovery system. 3 lines in parallel operation. Distillation process- Product pumped through horizontal Distillation kettles with steam Re-Boilers and Distillation Columns with shell and tube Condensers.
  • PRIMARY PRODUCT(S):Glycol, Ethanol.
  • PRIMARY PROD.CAPACITY:300gpm total feed. 100gpm per line.
  • PRIMARY PROD.DETAIL:4 Fractions per Line- #1 Methanol. Line #2 Off-Specs, Line #3 Distilled Glycol, Line #4 Off-Specs
  • SECONDARY PRODUCT(S):Water
  • MAT'LS CNSTRN-CONTACTS:316SS product & CS
  • INSTALLATION AREA:70' x 100'
  • PRIOR SERVICE:Nylon Polymer production. Last use 2003 approx.
  • COMMENTS:Installed, units side by side in 3 story open frame structure. Flow controllers, Temperature controllers, High/Low level alarms. Control room for all 3 units. Documentation. Heating Exchangers rated 400# @ 480 Deg F shellside, FV tubeside in general. Cool
  • SHIPPING SIZE-W X H X L:8'W X 10'H X 50'L
  • APPROX. WEIGHT-LBS:300000#
  • QUANTITY:1