- MFD.BY:General Electric, Lynn, MA
- DATE MFD:1970's approx
- TYPE:Steam Turbine, propulsion unit.
- MODEL:MST-19 LP Marine
- RATED-HP:22780
- TURBINE-TYPE:Condensing
- No.STAGES:9
- EXTRACTION:85#
- INLET STEAM:110psig est. [285# @ 490Deg F.Casing test pressure] Nozzle 24"
- EXHAUST STEAM:30#/FV [Casing test pressure]
- GOVERNOR:Woodward or similar
- ROTATION:CW from Governor end.
- PRIOR SERVICE:UNUSED
- COMMENTS:Cancelled Supertanker project. Vessel 1200'long, 390,000tons. Turbine new cost $1.5mm approx. Rotor is a solid forging, 9-stage Ahead, Reaction. Steam Rate 5.34Lbs/SHP-Hour
- SHIPPING SIZE-W X H X L:13'W X 12'H X 15'5"L
- APPROX. WEIGHT-LBS:67750#
- QUANTITY:1